Installation manual

Configuration Mode (ConF)
94 S1A28692 03/2010
Parameters described in this page can be accessed by:
Asynchronous motor parameters
Code Name / Description Adjustment range Factory setting
ASY- [ASYNC. MOTOR]
Only visible if [Motor control type] (Ctt) page 92 is not set to [Sync. mot.] (SYn).
nPr [Rated motor power]
According to drive rating According to drive rating
g
This parameter cannot be accessed if [Motor control type] (Ctt) page 92 is set to [Sync. mot.] (SYn ).
Rated motor power given on the nameplate, in kW if [Standard mot. freq] (bFr) is set to [50Hz IEC] (50), in HP if
[Standard mot. freq] (bFr) is set to [60Hz NEMA] (60).
COS
[Motor 1 Cosinus Phi]
0.5 to 1 According to drive rating
g
Nominal motor cos phi.
This parameter can be accessed if [Motor param choice] (MPC) is set to [Mot Cos] (COS).
UnS [Rated motor volt.]
100 to 480 V According to drive rating and
[Standard mot. freq] (bFr)
g
This parameter cannot be accessed if [Motor control type] (Ctt) page 92 is set to [Sync. mot.] (SYn ).
Rated motor voltage given on the nameplate.
nCr [Rated mot. current]
0.25 to 1.5 In (1) According to drive rating and
[Standard mot. freq] (bFr)
g
This parameter cannot be accessed if [Motor control type] (Ctt) page 92 is set to [Sync. mot.] (SYn ).
Rated motor current given on the nameplate.
FrS [Rated motor freq.]
10 to 800 Hz 50 Hz
g
This parameter cannot be accessed if [Motor control type] (Ctt) page 92 is set to [Sync. mot.] (SYn ).
Rated motor frequency given on the nameplate.
The factory setting is 50 Hz, or preset to 60 Hz if [Standard mot. freq] (bFr) is set to 60 Hz.
nSP [Rated motor speed]
0 to 65,535 rpm According to drive rating
g
This parameter cannot be accessed if [Motor control type] (Ctt) page 92 is set to [Sync. mot.] (SYn).
0 to 9,999 rpm then 10.00 to 65.53 krpm on the integrated display terminal.
If, rather than the rated speed, the nameplate indicates the synchronous speed and the slip in Hz or as a %, calculate the rated
speed as follows:
Nominal speed = Synchronous speed x
or
Nominal speed = Synchronous speed x (50 Hz motors)
or
Nominal speed = Synchronous speed x (60 Hz motors).
100 - slip as a %
100
50 - slip in Hz
50
60 - slip in Hz
60
DRI- > CONF > FULL > DRC- > ASY-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com