Specifications

Installation
2–2 975-0298-01-01
Installing the Xantrex XW System Control Panel
The Xantrex XW System Control Panel is designed to be wall mounted
(see page 2–7), and requires no connections other than Xantrex Xanbus
network cables or a terminator plugged into the back of the unit.
Because you cannot access the Xantrex XW SCP network inputs once
the unit is mounted, the Xantrex Xanbus cables must be routed through
the wall and connected before securing the Xantrex XW SCP.
Materials and Tools Required
The following materials and tools are required to complete the
installation:
Mounting template sticker (supplied)
Mounting plate (supplied)
Mounting bracket (supplied)
Four #6 screws (supplied)
Two #8 screws (supplied)
Cable clamps or hardware fasteners
Xantrex Xanbus network cables or equivalent (CAT 5 or CAT 5e cable
with RJ-45 connectors wired to T568A standard. One 2.1 meter
cable is supplied
Two network terminators (one terminator is supplied with the Xantrex
XW SCP and each Xantrex Xanbus-enabled device)
Phillips head screwdriver
Jigsaw or small keyhole saw
Power drill with 1/8" bit (optional)
Choosing a Location
Choose a location that allows unobstructed access to the Xantrex XW
SCP screen and buttons.
The location should be indoors, dry, and free from corrosive or explosive
fumes.
WARNING: Explosion hazard
The Xantrex XW SCP is not Ignition Protected. Do not install in areas
requiring Ignition-Protected equipment, such as areas containing
gasoline engines, tanks, or fuel-line fittings.