Troubleshooting Reference
Types of Faults and Warnings
The various types of fault and warning messages behave differently, and
give you the option to treat them differently when they appear. For more
information about the types of fault and warning messages, see “Types”
on page 4–4 and “Types of fault messages” on page 4–7.
Warning Reference Table
Table 5-1 Warning Reference Table
Warning
number Message
Message
(translation) Type Cause Action
W250 The value failed
to change.
Try again.
Automatic A Xantrex
Xanbus-enabled
device rejected
the new setting.
A temporary
communication
problem
stopped the
Xantrex XW SCP
changing a
value that you
entered.
Check device
operation guide
and settings.
The setting may
be out of range,
the system mode
may be incorrect,
or another device
setting is
overriding the
setting you want
to change.
Try changing the