Item Description
Low Battery Cut
Out Delay
Low Battery Cut Out Delay controls how long the inverter is
allowed to operate at or below the Low Battery Cut Out level
before turning off due to a low battery voltage condition. The
inverter will stop producing AC output only after the Low Battery
Cut Out level has been reached for this uninterrupted period of
time.
Once the inverter has shut off, the battery voltage must rise the
amount of volts set in Low Battery Cut Out Hysteresis
above the Low Battery Cut Out setting for inverter operation to
resume.
Low Battery Cut
Out Hysteresis
The voltage increment on top theLow Battery Cut Out
parameter above which the battery voltage must be for inverter
operation to be allowed to resume.
High Battery Cut
Out
High Battery Cut Out sets the maximum battery voltage at
which the inverter will operate. If the battery voltage exceeds this
limit for more than 1 minute, the Conext XW Pro displays a fault
message (F49) and shuts down. The inverter will not support AC
loads when in this condition. If a qualified AC source is present, the
unit passes AC through to the loads. The inverter automatically
restarts when the voltage drops to 6volts below the High Battery
Cut Out setting. If battery voltage continues to rise after shutdown,
an external charger may still be charging the batteries. The Conext
XW Pro cannot control how external chargers operate.
High Battery Cut
Out Delay
High Battery Cut Out Delay controls how long the inverter is
allowed to operate at or above the High Battery Cut Out level
before turning off due to a high battery voltage condition. The
inverter will stop producing AC output only after the High
Battery Cut Out level has been reached for this uninterrupted
period of time.
Search Mode
Enable or disable Search Mode.
Maximum Search
Watts
Maximum Search Watts sets search sensitivity for the Conext XW
Pro when search mode is enabled. When a load larger than this
setting is present on AC OUT, the inverter starts producing AC
output from battery power. Enabling search mode from the same
menu can minimize power draw from the battery during periods of
low demand from loads. Note that energy-efficient light bulbs may
not provide enough power to wake the inverter from Search mode.
Conext XW Pro Owner's Guide Configuration
56 This document is intended for use by qualified personnel 990-91227A-01