Conext XW PRO 6848 6,800W 48V Installation

Table Of Contents
Item Description Default Range
Inverter
Mode
For a multi-unit system to
operate in single and split
configurations, one Conext
XW Pro must be configured
to Master and the rest as
Slave, otherwise a system-
wide fault is asserted.
For multi-cluster two or three
phase systems, only one
multi-phase cluster is to be
comprised of Masters of their
respective phases (Phase 1
Master, Phase 2 Master,
Phase 3 Master), and the
remaining clusters as Slaves
of their respective phases
(Phase 1 Slave, Phase 2
Slave, Phase 3 Slave).
Split
Phase
Master
Invalid
Single Phase
Stand Alone
Master
Slave
Split Phase
Stand Alone
Master
Slave
Two Phase
Phase 1 Master
Phase 1 Slave
Phase 2 Master
Phase 2 Slave
Three Phase
Stand Alone
Master
Slave
Phase 1 Master
Phase 1 Slave
Phase 2 Master
Phase 2 Slave
Phase 3 Master
Phase 3 Slave
Table 13Multi-Unit Configuration Menu
For default settings, see "Multi-unit Configuration Menu" on page190.
Conext XW Pro Owner's Guide Configuration
84 This document is intended for use by qualified personnel 990-91227A-01