Conext SW4048 4,000W 48V Installation

Table Of Contents
Specifications
6–4 975-0638-01-03
AC Transfer Specifications
NOTE: All transfer specifications are at nominal conditions: ambient temperature
of 77 °F (25 °C), split-phase 120/240 VAC, 60 Hz input, unless otherwise
specified.
With a battery temperature
sensor (provided)
The temperature compensation coefficients on
a 24-volt battery
are as follows:
Flooded: 54 mV × (25 °C – BTS °C)
Gel: 54 mV × (25 °C – BTS °C)
AGM: 42 mV × (25 °C – BTS °C)
The temperature compensation coefficients on
a 48-volt battery
are as follows:
Flooded: 108 mV × (25 °C – BTS °C)
Gel: 54 mV × (25 °C – BTS °C)
AGM: 42 mV × (25 °C – BTS °C)
AC Input
SW 2524 120/240 SW 4024 120/240 SW 4048 120/240
Power factor at full charge rate > 0.98 > 0.98 > 0.98
Current 9A 13A 12A
Voltage 120/240 VAC 120/240 VAC 120/240 VAC
Voltage range
single-phase/split-phase
95/190 VAC to
135/270 VAC
95/190 VAC to
135/270 VAC
95/190 VAC to
135/270 VAC
Frequency range 44
70Hz 44
70 Hz 44
70 Hz
AC INPUT Connection Split-phase
(L1/L2)
Split-phase
(L1/L2)
Split-phase
(L1/L2)
a.Charging current derates up to 5% between 35 to 60 °C.
b.Recharging does not occur when battery voltage is below 12 V.
DC Output
SW 2524 120/240 SW 4024 120/240 SW 4048 120/240
All Models
Transfer time—utility to invert < 20 ms
Relay current rating
30 A
a
a.Limited by SCP to 24 A due to CEC/NEC regulatory requirements.
Minimum line-to-neutral AC input
voltage for transfer
95 VAC RMS
Maximum
line-to-neutral
AC input
voltage for transfer
135 VAC RMS
Minimum AC input frequency for transfer
44 Hz
Maximum AC input frequency for transfer
70 Hz
Cooling Fan-cooled, temperature controlled