Conext SW4048 4,000W 48V Installation
Table Of Contents
- Conext™ SW Inverter/Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-03 Revision: Date: 5-2020
- Contact Information solar.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Safety Information
- Precautions When Working With Batteries
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Basic Protection Features
- Grid-interactive and Other Features
- Load Shaving
- AC Support
- Grid-Interactive Delay Feature
- AC Coupling
- AC Couple Smart Charge
- Storing the State of the Inverter Mode
- NoLoadVD
- Low Battery Cut Out Hysteresis
- LBCO Delay
- Lithium Ion Battery Type
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- AC Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Advanced Features Menu
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Components and Mechanical Features
2–2 975-0638-01-03
System Components
The Conext SW uses Xanbus, a network communications protocol developed to
send Conext SW’s operational settings and status to other Xanbus-enabled
devices. You can configure and monitor the Conext SW and every Xanbus-
enabled device in the system using an optional System Control Panel (SCP).
Another component is the optional Automatic Generator Start (AGS) which allows
operation with a wide range of generators, supported through a dedicated
generator input. Simply, the AGS automatically starts and stops your generator.
Solar charge controllers allow renewable energy collected from the sun to charge
batteries as might be the case in an off-grid application of Conext SW. The
charge controllers form part of the Xanbus network.
See “Xanbus-enabled Products and Other Accessories” on page 2–3 for part
numbers.
Xanbus System
The Xanbus system includes the Conext SW and other Xanbus-enabled devices.
The Conext SW is the device in a Xanbus system that typically provides network
power—500 mA at 12 VDC. All of the Xanbus-enabled devices, such as the
Conext SW, the SCP, and the AGS are able to communicate their settings and
activity to each other.
The Xanbus-enabled designation (see left) means that this product works on a
Xanbus network. Xanbus-enabled products are:
• Simple to operate and routine tasks are automated.
• Controlled by software that eliminates analog signalling errors.
• Less susceptible to interference and line loss.
• Upgradable through new software releases.
Figure 2-1 Xanbus System Components
Xanbus System Control Panel
Xanbus Automatic Generator Start
MPPT 60 150
Solar Charge
Controller
SCP
AGS
Conext SWXanbus Network _ _ _ _ _ _ _ _
network terminator network terminator
Conext
ComBox
TM