Inverter/Charger Operation using the System Control Panel (SCP)
975-0638-01-03 3–9
SCP Features
Feature Description
1 Fault/Warning light indicates a device has a fault detection or warning
condition and requires attention. The light flashes when a warning
occurs and turns on steadily when a fault detection occurs.
2 Enter button confirms selection of a menu item or displays the next
screen.
3 Up arrow button scrolls upward through screen text or increases a
selected value.
4 Down arrow button scrolls downward through screen text or
decreases a selected value.
5 Exit button cancels selection of a menu item or displays the previous
screen.
6 Screen shows menus, settings, and system information.
7 Standby button disables inverting and charging on all Conext SW
units in the system when pressed and held for one to two seconds. To
enable inverting and charging, press and hold the Standby button
again for one to two seconds.
En t e r Ex i t
Fa ul t / Wa r n i n g
Standby
1