Conext SW4048 4,000W 48V Installation

Table Of Contents
Operation
3–10 975-0638-01-03
Using the Standby Button
The Standby button has two functions, depending on how it is pressed. First,
when only the Standby button is pressed, it can disable inverting and charging
for all Conext SW units in the system. Second, when it is pressed simultaneously
with the Exit button, this action puts the entire system into Standby mode.
Pressing the Standby button produces the same result as disabling “Invert” and
“AC Charge” from the System Settings menu on the SCP. Pressing the Standby
button momentarily affects only Conext SW units; it does not affect charge
controller operation. After disabling inverting and charging with the Standby
button, the system continues to pass AC input through to the loads.
Pressing the Exit and Standby buttons at the same time puts the entire Xanbus
network system (including charge controllers) into Standby mode. In Standby
mode, the Conext SW stops passing AC input through to the loads.
After the keypress command to enter Standby mode, the AGS – Automatic
Generator Start (if installed) shuts down the generator (if it is running) after a
cool-down cycle.
SCP Navigation
This section describes the different types of screens and menus on the SCP. To
monitor Conext SW operation and change settings, it is helpful to know how to
locate these screens and menus.
Startup Screen
This screen is shown when the SCP first receives power from the Xanbus
network.
Figure 3-1 Startup Screen
En t e r Ex i t
Faul t /Warning
Standby