Conext SW4048 4,000W 48V Installation

Table Of Contents
Operation
3–12 975-0638-01-03
The System Status screen displays:
Qualified AC source (if applicable) and total power to and from the source
Battery capacity and voltage level
Net battery input or output current
Total inverter loading
Time and date
Conext SW Home
Screen
The Conext SW Home screen is the first of the Device Home screens. Each Conext
SW installed in the system has its own Home screen. The screen appearance
varies with the status of each inverter/charger. The Conext SW Home screen
displays real-time operating data specific to the Conext SW. The Conext SW
status changes according to the states described in Table 3-2 on page 3–13.
To display the Conext SW Home screen:
u While viewing the System Status screen, press the down arrow key.
IMPORTANT: If you are uncertain which SCP screen or menu you are viewing,
you can always return to the starting point—the System Status screen—by
pressing Exit repeatedly until the screens stop changing.
Figure 3-3 System Status Screen
System Status
Battery
BatLev
Load
AC1
13.8A 24.0V
E--F
1750W
240V 1750W
menu 12:53PM Aug 13
Line 1: Battery input/output current and voltage
Line 2: Battery level meter
Line 3: Power supplied to loads
Line 4: AC input source and line-to-line voltage
The menu arrow indicates the
Enter button. Press Enter to
display the Select Device menu.
Figure 3-4 Conext SW Home Screen
CSW4024 00: Home
Status
Battery
Load
AC In
Invert
-16.4A 26.2V
1750W
0.0V 0W
setup system
Top Line: Device name and number
Line 1: Inverter/charger status
Line 2: Battery current (in + or out –) and voltage
Line 3: Power supplied to loads
Line 4: AC input status
The setup arrow indicates the Enter
button. Press Enter to display the
inverter/charger setup menu.
The system arrow indicates the
Exit button. Press Exit to display
the System Home screen.