Conext SW4048 4,000W 48V Installation
Table Of Contents
- Conext™ SW Inverter/Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-03 Revision: Date: 5-2020
- Contact Information solar.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Safety Information
- Precautions When Working With Batteries
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Basic Protection Features
- Grid-interactive and Other Features
- Load Shaving
- AC Support
- Grid-Interactive Delay Feature
- AC Coupling
- AC Couple Smart Charge
- Storing the State of the Inverter Mode
- NoLoadVD
- Low Battery Cut Out Hysteresis
- LBCO Delay
- Lithium Ion Battery Type
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- AC Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Advanced Features Menu
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Configuring Advanced Settings
975-0638-01-03 4–35
Restoring Factory Default Settings
The Restore Defaults command returns the Conext SW to factory default
settings. After using the Restore Defaults command, the Conext SW is no
longer configured for the power system.
To restore Conext SW default settings:
1. On the Advanced Setup menu, select Restore Defaults.
Event code W252 appears, asking to confirm the Restore Defaults
command.
2. To cancel the command, press Exit. To continue with the Restore Defaults
command, press Enter.
NOTICE
EQUIPMENT DAMAGE
Do not use the Restore Defaults command while the Conext SW is
operating. De-energize the power system and disconnect the Conext SW AC
input before using the Restore Defaults command. Reconfigure the Conext
SW before reconnecting the AC input and re-energizing the power system.
Failure to follow these instructions can damage the inverter/charger.
IMPORTANT: If a warning is already active in the system, selecting Restore
Defaults brings up the Warning List, with warning W252 at the top. Press Enter to
view W252 and continue with the Restore Defaults process.
IMPORTANT: Restoring to default may mean that the AC output frequency will
change back to 60 Hz. When the change happens, event code W298 appears.
See “EuroFreq Feature” on page 4–36 for information on changing the AC output
frequency to 50 Hz, if desired.