Conext SW4048 4,000W 48V Installation
Table Of Contents
- Conext™ SW Inverter/Charger
- Exclusion for Documentation
- Document Number: 975-0638-01-03 Revision: Date: 5-2020
- Contact Information solar.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Safety Information
- Precautions When Working With Batteries
- FCC Information to the User
- Introduction
- Materials List
- Key Features
- Key Features Explained
- Basic Protection Features
- Grid-interactive and Other Features
- Load Shaving
- AC Support
- Grid-Interactive Delay Feature
- AC Coupling
- AC Couple Smart Charge
- Storing the State of the Inverter Mode
- NoLoadVD
- Low Battery Cut Out Hysteresis
- LBCO Delay
- Lithium Ion Battery Type
- Components and Mechanical Features
- System Components
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Conext SW Inverter/Charger Mechanical Features
- Conext SW Front and Side Panels
- Operation
- Start Up Behavior
- Inverter Operation Using the Front Panel
- Operating Limits for Inverter Operation
- Operating Limits for Charger Operation
- Inverter/Charger Operation using the System Control Panel (SCP)
- SCP Features
- Using the Standby Button
- SCP Navigation
- Changing Operational Settings
- Configuration via SCP
- Viewing the Firmware Revision Number
- Setting the Time and Date
- Viewing the Basic and Advanced Settings Menus
- Configuring Basic Settings
- Configuring Advanced Settings
- Inverter Settings Menu
- Charger Settings Menu
- AC Settings
- AC Support Settings
- Multi Unit Config Menu
- Restoring Factory Default Settings
- Advanced Features Menu
- Configuration Sheet
- Troubleshooting
- General Troubleshooting Guidelines
- Inverter Applications
- View Device Info Logs
- Troubleshooting the Conext SW via the SCP
- Fault Detection Types
- Warning Types
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
Configuration via SCP
4–36 975-0638-01-03
Advanced Features Menu
EuroFreq Feature
The default inverter AC output frequency is 60 Hz.
To change the inverter AC output frequency to 50 Hz:
1. Put the system in Standby mode. See “To change an operational setting” on
page 3–18.
2. Change the EuroFreq to Enabled. See “To select and change a configurable
setting:” on page 4–6.
Figure 4-12 Adv Features Menu Screen
Table 4-19 Adv Features Description and Values
a
a.Applies to all Conext SW models.
Setting Description Default Range
EuroFreq
When enabled, sets the AC
output frequency to a constant
50Hz.
Disabled Enabled,
Disabled
StoreInv
State
See “Storing the State of the
Inverter Mode” on page 1–15.
Enabled Enabled,
Disabled
AcCouple
For information on this feature
refer to the AC Coupling
Solutions Guide.
Disabled Enabled,
Disabled
Enhanced
ACSup
See “Enhanced AC Support”
on page 1–9.
Disabled Disabled,
Enabled
PLSDelay
Delays load shaving and AC
support features until the
MPPT has charged the battery
in float mode for 2 hours. See
“Grid-Interactive Delay
Feature” on page 1–11.
Disabled Disabled,
Enabled
NoLoadVD
See “NoLoadVD” on page 1–
15.
Disabled Enabled,
Disabled
CSW4024 00: Adv Fea
EuroFreq
StoreInvState
AcCouple
EnhancedAcSup
PLSDelay
NoLoadVD
[Enabled]
[Enabled]
[Disabled]
[Disabled]
[Disabled]
[Disabled]
[*Enabled] [Disabled]
[Enabled] [*Disabled]
[Enabled] [*Disabled]
[Enabled] [*Disabled]
CSW4024 00: Adv
Inverter Settings
Charger Settings
AC Settings
AC Support
Multi Unit Config
Restore Defaults
Adv Features
See “To select and change a configurable setting:” on page 4–
6 to change the settings.