Configuration via SCP
4–36 975-0638-01-03
Advanced Features Menu
EuroFreq Feature
The default inverter AC output frequency is 60 Hz.
To change the inverter AC output frequency to 50 Hz:
1. Put the system in Standby mode. See “To change an operational setting” on
page 3–18.
2. Change the EuroFreq to Enabled. See “To select and change a configurable
setting:” on page 4–6.
Figure 4-12 Adv Features Menu Screen
Table 4-19 Adv Features Description and Values
a
a.Applies to all Conext SW models.
Setting Description Default Range
EuroFreq
When enabled, sets the AC
output frequency to a constant
50Hz.
Disabled Enabled,
Disabled
StoreInv
State
See “Storing the State of the
Inverter Mode” on page 1–15.
Enabled Enabled,
Disabled
AcCouple
For information on this feature
refer to the AC Coupling
Solutions Guide.
Disabled Enabled,
Disabled
Enhanced
ACSup
See “Enhanced AC Support”
on page 1–9.
Disabled Disabled,
Enabled
PLSDelay
Delays load shaving and AC
support features until the
MPPT has charged the battery
in float mode for 2 hours. See
“Grid-Interactive Delay
Feature” on page 1–11.
Disabled Disabled,
Enabled
NoLoadVD
See “NoLoadVD” on page 1–
15.
Disabled Enabled,
Disabled
CSW4024 00: Adv Fea
EuroFreq
StoreInvState
AcCouple
EnhancedAcSup
PLSDelay
NoLoadVD
[Enabled]
[Enabled]
[Disabled]
[Disabled]
[Disabled]
[Disabled]
[*Enabled] [Disabled]
[Enabled] [*Disabled]
[Enabled] [*Disabled]
[Enabled] [*Disabled]
CSW4024 00: Adv
Inverter Settings
Charger Settings
AC Settings
AC Support
Multi Unit Config
Restore Defaults
Adv Features
See “To select and change a configurable setting:” on page 4–
6 to change the settings.