Full Product Manual

• 5 •
Override Mode
If the Standard mode fails, follow these
steps to use Override mode:
NOTE: The GLOW function will not operate
in this mode.
• Always read the vehicle manufacturer’s
instruction manual.
An initial battery indication of below 12V
may suggest that there is an internal fault.
1. Pre-charge the ProBooster, using
one of the “Alternative Pre-Charge
Methods”.
2. Remove the vehicle’s positive (red)
lead from the battery terminal (g. 1).
Ensure that the ProBooster is switched
off. Connect the ProBooster’s positive
clamp to the vehicle positive lead, NOT
the battery terminal (g.1).
3. Press the ON/OFF button. NOTE: the
ProBooster will switch off if not used
within 2 minutes; restart the process if
this happens. Press and hold the ON/
OFF button until the Override/Fault
indicator ashes green. This indicates
that Override mode is initializing. When
the Indicator shows a steady green,
the Override mode is active.
4. Start the engine. (The ability for an
engine to continue to run without a
battery connected will vary, depending
on the make and model of the vehicle).
WARNING: Do not leave the engine
running without the ProBooster or the
battery being connected. Failure to
comply could result in damage to the
vehicle ECU. The manufacturer will not
accept responsibility for any damage
caused by incorrect use of this product.
5. As soon as the engine starts, and
keeping the ProBooster clamp and
battery lead connected, attach the
positive lead to the positive battery
terminal and tighten the terminal clamp
(g. 2). After the positive lead has been
secured to the battery terminal switch
off the ProBooster and disconnect from
the battery.
Glow Mode:
In cold weather, the glow plugs in most
diesel vehicles will energize rst to heat
up the engine chamber before the engine
start, as indicated by the GLOW sign on
the dashboard. The process needs a
current of 40-60Amp and takes about 4-6
seconds. In this case, after the ProBooster
is fully recharged and connected, press the
GLOW button, and then turn on the ignition.
NOTE: GLOW is inactive under Override
Mode.
Condition Indicator
The condition indicator turns RED under
following conditions:
• Reverse connection
Battery voltage is lower than 3 Volt
The Condition indicator turns GREEN under
Override Mode.
The Condition indicator blinks between
RED and GREEN under Glow mode.
Working Cycle
MODEL
MAXIMUM
OPERATIONS
IN A ROW
MINIMUM INTERVAL
BETWEEN
SESSIONS
DSR108 5 times 15 minutes
DSR109 3 times 20 minutes
IMPORTANT: Allow sufcient cooling time
between two working sessions. Failure to do
so may cause damage to the ProBooster.