Owner`s manual

36
Static Handlebar If tests reveal no other issues, the
console handlebar assembly should be
replaced.
Console displays “E2” error
code
Check data cable integrity All wires in cable should be intact. If any
are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Console Electronics If tests reveal no other issues, Console
should be replaced.
No speed/RPM reading, or
Console displays “E3” error
code
Check data cable integrity All wires in cable should be intact. If any
are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Check magnet position
(requiresshroudremoval)
Magnet should be in place on pulley.
Check RPM Sensor (re-
quiresshroudremoval)
RPM sensor should be aligned with
magnet and wiring should be intact.
Realign sensor if necessary. Replace if
there is any damage to the sensor or
the connecting wire.
Console shuts off (enters
sleep mode) while in use
Check data cable integrity All wires in the cable should be intact. If
any are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Reset machine Unplug unit from electrical outlet for 3
minutes. Reconnect to outlet.
Check magnet position
(requiresshroudremoval)
Magnet should be in place on pulley.