Air and Water Cooled Installation and User's Manual

Installation: Product Specifications
Location Limitations: The product is designed to be
installed indoors, in a controlled environment. Air
cooled models discharge very warm air into the
room out the back. Space must be allowed at the
left side and back for air intake and discharge.
Water cooled models discharge warm water into
the building’s drain. Space needs to be provided on
both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice
capacity of air cooled machines will be significantly
reduced with minimal clearance at the sides, back
and top. Some space is recommended for service
and maintenance purposes on all models.
6" of space at the sides and back are required for
adequate operation. To get the most capacity,
locate the machine away from heat producing
appliances and heating ducts. Provide several feet
of space to the left for maximum ice capacity.
Walls or other large machines near to the ice
machine might also cause a reduction in ice
capacity. One foot behind and two feet above will
be required to make rated capacity.
Airflow is in the front, in the left side, out the back
(as viewed from the front).
Environmental Limitations
Minimum Maximum
Air temperature 50
o
F. 100
o
F.
Water
temperature
40
o
F. 100
o
F.
Water pressure 20 psi 80 psi
Power supply – acceptable voltage ranges
Minimum Maximum
208-230 volt
model
198 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
November 2006
Page 2
C1448, C1848, C2148W
Air and Water Cooled User Manual
Airflow Direction