6 Installation
Caution!
DonotinstallDNFpanelinareawithpotentiallyammableorexplosivevapors.
1. Select panel location away from direct contact with water and oil.
2. Conrm clearance for wire connections behind wall, hull liner or bulkhead.
3. UsingDNFpaneltemplate(g.
6
, p. 9), cut out panel access hole and drill fastener holes.
4. Remove panel cover (g.
1
1, p. 2) from mounting frame (2), if necessary, by carefully pulling them
apart. Install mounting frame to wall with four fasteners (3).
5. Withelectricalpoweroff,routeproperwiringtoDNFpanellocation,makingsurewiresextendout
through access hole (g.
1
4, p. 2). Refer to wiring diagrams (g.
3
, p. 2, gs.
4
and
5
, p. 3)
for appropriate toilet system. Make nal wiring connections.
6. Push panel cover onto mounting frame until it locks.
7. TurnonelectricalpowertoDNFpanelandtoiletsystem.Conrmnormaloperationofstatuslight.
7 Operation
7.1 Vacuum status monitor (in VacuFlush system)
WhenelectricalpowertotoiletsystemisturnedONandtheDNFpanelred light glows, this indicates
thatthereisNOTsufcientvacuuminthesystemtoushthetoilet.Do not flush toilet, or blockage
may occur.
Notes
WhenconnectedtoaVacuFlushtoiletsystemandredlightconstantlycyclesonandoff
betweenushes,thereisapossiblevacuumleakinthesystem.(AnidleVacuFlushsystem
should not cycle more frequently than once every three hours.)
If red light is OFF but there is no vacuum in system, a blockage has likely occurred
betweenthetoiletandvacuumtank.Openushballintoiletbowlandusestandardtoilet
plunger to unblock.
After a period of time, if red light seems to remain lit longer than when toilet system was
new, duckbill valves in vacuum pump may require replacement.
Caution!
IfDNFisconnectedtoa“full”tanklevelsensororshut-downrelayandholdingtankis
empty, a continuous red light may indicate extensive vacuum loss due to blockage, pump
failure or leak. Turn off vacuum system and repair as soon as possible.
7.2 “Full” tank monitor (in VacuFlush system)
WhenelectricalpowertotoiletsystemisturnedON,theredlightglows,andthevacuumpumpisnot
running, this indicates that the holding tank is full and needs to be pumped out. Do not flush toilet, or
blockage may occur.
7.3 “Full” tank monitor (in other marine toilet system)
WhenelectricalpowertotoiletsystemisturnedONandtheredlightglows,thisindicatesthatthe
holding tank is full and needs to be pumped out. Do not flush toilet, or holding tank may overfill and
damage toilet system components or boat.
DNF Panel Template
Dimensions (g.
6
, page x)
Ref. Dimension
A 83 mm / 3.25 in.
B 83 mm / 3.25 in.
C 67 mm / 2.63 in.
D 67 mm / 2.63 in.
E 55 mm / 2.16 in.
F 68 mm / 2.69 in.
G 2 mm / 0.10 in. dia.
H Access hole.
Allow 51 mm / 2 in.
clearance behind
wall.
Installation SeaLand DNF Status Panel