1 2 3 4 5 6 Do not look directly at the lamps, without UV protective glasses. Read instruction manual before operating the units. Use recommended accessories (i.e. lamps, ballast) Make sure unit is installed so that the UV light can not be seen directly through any returns or supplies. Check damaged parts: Before further use of the unit, any damaged part should be carefully checked to ensure that the unit will operate properly. Any part that is damaged should be properly repaired or replaced.
WARRANTY LIMITATIONS This warranty will be voided if the covered equipment (only second wind replacement parts or units are warranted) is removed from the original installation site. This warranty does not cover damage or defect resulting from: 1 Accident, or neglect or unreasonable use or operation of the equipment, including operation of electrical equipment at voltages other than the range specified on the unit name plate.
PAGE Safety Concerns Warranty Unpacking Installation Locations Installation 1000 Series Lamp Replacement Troubleshooting Replacements Parts 1000 Series Cut Sheet 1000 Series Cut Sheet 2 2-3 4 5 6 7 8 8 9 10 Your new Second Wind Air Purifier is shipped complete in one container. Carefully unpack the unit and all loose items from the shipping container. Figs. 2 illustrate the unit and all loose items packed with the unit.
The Second Wind Air Purifier has been tested effective in the destruction and reduction of bacteria, viruses and fungus under various conditions. The effectiveness of this device may vary depending upon room area and rate of circulation. The health aspects associated with this product were not investigated by U.L. WARNING!!! DO NOT LOOK AT THE ULTRA-VIOLET LIGHT DO NOT OPERATE UNTIL IT IS INSTALLED IN THE RETURN OR SUPPLY. TO DETERMINE AN INSTALLATION LOCATION SEE: FIG.
• • • • Installation should be done by a qualified HVAC contractor. Read all safety instructions at the beginning of this manual. Make sure unit is installed so that the UV light can not be seen directly through any returns or supplies. Units should not be installed with in 12-18 inches of any non UV resistant materials. If materials are in question call manufacturer of said products to see if they are made with UV inhibitors. Prolonged UV exposure will degrade non UV resistant materials.
Second Wind Air Purifier lamps are designed to be on all the time. After approximately 9000-11000 hours of operation the lamps intensity will decrease. Installation of a replacement lamps is best handled by a HVAC Contractor. Both lamps must be replaced at the same time for the MODEL 1000KCS. 1 Turn unit off and make sure the power is off to the unit. Wait for lamp to cool. 2 Remove screws from around the unit, do not remove the screws from the hinge. (Fig.
1 2 3 4 5 Make sure that the unit is wired properly and is turned on. 1002KCS • Check the on/off switch to make sure it is on. If the lamp is still not on, switch the unit off, disconnect power and check the fuse. Make sure the lamp is not broken and that it is in the socket. If the lamp is still not on, check the ballast . • 1000KCS units 1 2 3 4 5 For the 240 vac units 1002kcs the ballast resistance should be tested like before. Disconnect power.
Since the first ultraviolet irradiation system was used successfully in 1909, ultraviolet irradiation has had a 94 year performance history. Second Wind uses the ultraviolet wavelength at 253.7nm, ultraviolet radiation lethal to microorganisms. Second wind air purifiers can reduce mold, bacterial, or viral airborne microbes in all areas of a Heating Ventilation and Air Conditioning system (HVAC).
Second Wind Air Purification 1000KCS and 1002KCS units are mounted in the return to accommodate most HVAC systems. The units install anywhere in the system to disinfect molds, bacteria or reduce VOC contamination. The housing is steel and comes in 2 sizes (9” and 18” lamps). All units are manufacturer assembled and tested. Models 1002KCS: The power source is a electronic, Class P, Sound rated A, Type HL, NO PCB’s, type 1 outdoor ballast meeting EMI requirements of CFR Title 47 Part 18 consumer.