User's Manual

6
1 Use the metal template/mounting bracket to
pencil out rectangle to cut out. (Fig.4)
2 Use the drill and a 1/2 inch drill bit to cut a
hole along the inside of the marked circle.
(Fig.5)
3 Use tinsnips to cut out the rectangle (Fig.6).
4 Make sure lamps on the 1000 series units are
pointed in the direction of the airflow. There
are arrows pointing to the direction the air must
pass across the lamps. If not, remove the lamps
from the brackets and turn them around.
5 Install mounting plate around opening in duct
with zip screws. (Fig.7)
6 Use the self tapping sheet metal screws to
secure the unit to mounting template. (Fig.8)
7 Make sure the power is off to the blower be-
fore wiring unit.
8 For the 1000KCS : With the switch in the off
position, plug the unit directly into a 120 vac
outlet. Turn the switch to the on position.
9 The 1002KCS air purifier is designed to turn
on and off with the forced air blower. Wire the
unit into the HVAC system to come on and off
with the blower. If lamp is operating the sight
glass will illuminate. If it is not see the
troubleshooting section.
Installation should be done by a qualified HVAC contractor.
Read all safety instructions at the beginning of this manual.
Make sure unit is installed so that the UV light can not be seen directly through any returns
or supplies.
Units should not be installed with in 12-18 inches of any non UV resistant materials. If ma-
terials are in question call manufacturer of said products to see if they are made with UV
inhibitors. Prolonged UV exposure will degrade non UV resistant materials. Non UV resis-
tant materials must be shaded or covered .
1 Marker
2 Tinsnips
3 Drill
4 Drill Bits
5 5/16” &
11/32 “Nut
driver
6 Tape
Measure
7 Metal
Template
and
Mounting
Bracket