Second Wind Air Purifier lamps are designed to be on all the time. After approximately 9000-11000 hours of
operation the lamps intensity will decrease. Installation of a replacement lamps is best handled by a HVAC
Contractor.
Both lamps must be replaced at the same time for the MODEL 1000KCS.
1 Turn unit off and make sure the power is off
to the unit.
Wait for lamp to cool.
2 Remove screws from around the unit, do not
remove the screws from the hinge. (Fig.13)
3 Drop unit down, it will remain attached to the
duct via the hinge. (Fig.14)
4 Carefully remove lamp from brass lamp hold-
ers. (Fig.15)
5 Remove lamp connector from end of lamp.
(Fig.16 & Fig.17)
6 Install new lamp into socket and snap into
brass holders.
7 Return unit to upright position against duct
and re-attach with screws.
8 Power unit up and turn on.
NOTE
UV Lamps contain mercury like other
fluorescent lamps and must be disposed of
properly. Do not throw old lamps in the
trash. Contact your local waste collection
agency for proper disposal procedures.
If the lamps are dirty or have fingerprints
on them, use alcohol to remove. The
1000kcs purifier has 2– different lamps.
1. 1-split lamp part # 1068
2. 1– straight lamp part # 1068A