Quick start Guide

8
Checking Measured Value
This example explains how to observe exposure value using the
ambient light T value (shutter speed) priority mode.
F stop value (aperture) is displayed for ambient light and T
(shutter speed) priority mode.
Measuring
button
Measuring
Value
9
_
1
Measuring Modes (ambient light)
The following describes the other Ambient Light measuring modes
available to meet your shooting needs.
* The mode details appearing in bold font below are the modes
available in the default display mode. Measuring Modes can be
added or removed in the Custom Setting Mode.
Icon Mode Details
Ambient light T (shutter speed) priority mode
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
Ambient light F stop(aperture) priority mode
Displays shutter speed values for input shutter speed and
ISO values.
Ambient light TF (Shutter speed and F stop) priority mode.
Displays ISO value for input shutter speed and F-stop.
Ambient light HD Cine mode
Displays F-stop value for input shutter speed, frame rate and ISO
values.
Ambient light Cine mode
Displays F-stop value for input frame rate (f/s), ISO, and shutter
angle values.
Ambient light Illuminance (lux) mode
Displays brightness values in lux units.
Ambient light Illuminance (fc) mode
Displays brightness values in foot-candle units.
Ambient light Luminance (cd/m
2
) mode (by reected light
measurement using with accessory viewnder available as
separate purchase)
Displays brightness values in cd/m
2
units.
Ambient light Luminance () independent display mode (by
reected light measurement using with accessory viewnder
available as separate purchase)
Displays brightness values in foot-lambert units.
Icon Mode Details
Cordless mode
Detects flash brightness without meter-flash connection
after measuring button pressed to arm meter for 90 seconds
and flash fired separately.
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
Cordless multi (cumulative) ash mode
Detects and accumulates ash brightness without meter-ash
connection after measuring button pressed to arm meter for 90
seconds and ash red separately.
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
Cord (PC) mode
Detects flash brightness with PC cord meter-flash
connection.
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
Cord multi (cumulative) ash mode
Detects and accumulates ash brightness with PC cord meter-
ash connection.
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
Radio triggering mode *
Detects ash brightness without meter-ash connection after
radio transmitted trigger signal is received by radio-receiver
connected ash.
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
Radio triggering multi (cumulative) ash mode *
Detects and accumulates ash brightness without meter-ash
connection after radio transmitted trigger signal is received by
radio-receiver connected ash.
Displays f-stop values (apertures numbers) for input shutter
speed and ISO values.
* L-478DR only. PocketWizard
®
receivers are required to radio signal and
trigger ash.
9
_
2
Measuring Modes (ashlight)
Radio Control Function (for L-478DR only)
10
_
1
Setting Channels in Radio Triggering Mode
Using the Radio triggering mode with operations for using
PocketWizard
®
ControlTL
®
.
Setting ControlTL
®
Channel
1) Touch the Tool Box icon
at the bottom of
the Measuring screen to display the Tool Box
screen.
2) Touch the Radio CH/Zone button to display
the Radio Trigger Channel / Zone setting
screen. Then touch the CTL tab activate the
ControlTL settings.
3) Touch the arrows / or slide your nger
over the screen to select a channel from 1 to
20.
4) Touch one or more of the control zone buttons
(A,B,C) to select ash zones you want to use.
* In the display example, the channel number
20 is selected.
5) Touch the OK tab to conrm settings and
return to the Measuring screen. (Touch the
Cancel tab to cancel settings.)
* See the Operating Manual for the radio
receiver to learn about settings for the radio
receiver incorporated into the ash.
Zones
Channel numbers radio receiver
incorporated into the ash.
Radio Control Functions (for L-478DR only)
10
_
2
Channel Setting in Radio Triggering Mode
Using the Radio triggering mode with operations for using
PocketWizard
®
Standard Channels.
Setting Standard Channel
1) Touch the Tool Box icon
at the bottom of
the Measuring screen to display the Tool Box
screen.
2) Touch the Radio CH/Zone button to display
the Radio Trigger Channel / Zone setting
screen. Then touch the CTL tab to activate
the ControlTL settings.
3) Touch the arrows / or slide your nger
over the screen to select a channel from 1 to
32. Channels 1-16 provide single triggering(no
zone).
4) Select channel numbers17-32 to display zone
buttons A, B, C, D provide control of up to
four zones of lighting.
·
The displayed example below is for channel
number 32.
·
Touch the OK tab to conrm settings and
return to the Measuring screen. (Touch the
Cancel tab to cancel settings.)
* See the Operating Manual for the radio receiver
to learn about settings for the radio receiver
incorporated into the ash.
Zone
Channel numbers
Radio Control Functions (for L-478DR only)
11
_
1
Adjusting Flash Intensity
Setting the flash intensity with Power Control Functions.
1) Touch the Measuring Mode Selection button
top left of the Measuring screen enter the
Measuring Mode Selection Screen.
Touch the icon/button to select the Flash
Power Control Mode button and return to the
Measuring screen.
2) Touch the Power Control icon
to display
the Power Control screen.
3) Set ash intensity output at the Power Control
screen. Be sure to set the channel number
you are using. (See 10-1 for details.)
1.
Touch the Zone buttons you want to select.
When using ✔ControlTL
®
channel:
A to C buttons
1
are set at bottom.
When using ✔Standard channel:
A to D buttons
2
set in column.
1
2
8
3
4
5
6
7
Power Control screen
ControlTL+Standard17~32Ch
2
Power Control screen
ControlTL+Standard1~16Ch
1
Standard settings provide control of up to four zones of lighting indicated
as a Zone letter (A, B, C or D). It is not possible to activate Quad-triggering
control without rst selecting a channel 17-32, and a Quad-Triggering zone
(A, B, C or D).
Radio Control Functions (for L-478DR only)
11
_
2
Adjusting Flash Intensity
2. The Power Bar (Output Adjustment screen) for the selected
zone will become available.Hold down the Measuring button to
display the current ash intensity output at
3
and the Power
Bar in
4
above.
3. Either touch the plus/minus [+]/[–] symbols or move the bar with
your ngertip to set the values.
4. To select other zones and set values, repeat process 1 to 3
above.
5. The F value (f-stop) for each zone calculated out from the set
T(shutter speed) and ISO sensitivity value is displayed in
5
and
the average F value (f-stop) for all zones is displayed in
6
.
6. When ash modeling lamps are being used, touch
7
to
turn off the modeling lamp.
Touch
7
to turn on modeling lamps again if needed.
4) Pressing the Measuring button once will transmit information about
intensity change to the ash.
(At this time, the ash will be triggered, but the intensity will be the one
prior to intensity adjustment.)
To measure the intensity exposure of the flash after intensity
adjustment, the Measuring button must be pressed again.
5) Take a measurement by placing the meter at the position of the subject
with the Lumisphere facing toward the camera’s lens axis. The ash will be
triggered and the measured value (F value) at that time will be displayed.
6) Repeat process 4) and 5) of ash intensity adjusting until the desired F
values are obtained.
PocketWiazard
®
is a registered trademark of LPA Design.
SEKONIC CORPORATION
7-24-14, Oizumi-Gakuen-cho, Nerima-ku Tokyo
178-8686 JAPAN
TEL +81-3-3978-2335 FAX +81-3-3922-5229
http://www.sekonic.com
JR1297621