Quick Guide ADN PS

ADN PS | 9
Setting up the conference system
Setting up the conference system
Basic information on the set-up of the conference system
Regardless of the number of conference units and the room size, we recommend
the following procedure for setting up the conference system:
Decide if you require wired or mobile wireless c
onference units. You can also
combine wired and wireless conference units.
Plan the number of conference units required for your conference system. A
t
otal of 400 conference units (of which up to 150 can be wireless) can be used
in a conference system (the maximum number of ADN C1 or ADN-W C1 chair-
person units is limited to 10). Always take the largest possible number of par-
ticipants as a starting point.
If you are using wired
conference units:
Plan if simple cabling is sufficient or if you
require a redundant ring topology
(see page 5).
If necessary, calculate the number of ADN PS power supplies required (a maxi-
mum of 15 ADN PS power supplies can be
used in a conference system).
If necessary, calculate the maximum length of the
cabling in order to ensure
that all conference units connected are supplied with sufficient voltage (see
page 5).
Place the ADN CU1 central unit and, if necessa
ry, the ADN PS power supplies e.g.
in the electrical equipment room or in the conference room.
Place the conference units at the corresponding seats.
Put out a sufficient number of SDC CBL RJ
45 system cables in the required
lengths.
Setting up a small conference system with only the ce
ntral unit
For a small conference system, you do not require ADN PS power supplies. The con-
ference units can be directly connected to the ADN CU1 central unit (for detailed
information, refer to the instruction manual of the ADN CU1 central unit or to the
ADN system manual).
CAUTION
Product damage due to an unsuitable power supply!
If you connect standard network devices with RJ45
plugs (e.g. switches or network
cards) to the connection sockets PORT I , PORT II, DATA PS and / , the net-
work devices can be damaged due to an unsuitable power supply.
Only connect ADN C1 and ADN D1 conference units, ADN PS power supplies and
the ADN AM antenna module to the connection sockets PORT I , PORT II, DATA PS
and / .
For detailed information on the ADN wireless components, refer to the ADN
system manual.