Quick Guide ADN PS
Table Of Contents
- Contents
- For your safety
- The ADN PS power supply
- Package contents
- Components required for operation
- Product overview ADN PS power supply
- Structuring and controlling the conference system
- Preparing the ADN PS power supply for operation
- Setting up the conference system
- Basic information on the set-up of the conference system
- Setting up a small conference system with only the central unit
- Connecting ADN PS power supplies to the ADN CU1 central unit
- Setting up a large conference system comprising ADN PS power supplies and conference units connected in cable strings
- Setting up a large conference system comprising ADN PS power supplies conference units connected in redundant ring topology
- Switching the ADN PS power supply on/off
- Cleaning and maintaining the conference system
- Specifications ADN PS
Switching the ADN PS power supply on/off
14 | ADN PS
Switching the ADN PS power supply
on/off
Switching the conference system on
왘 On the ADN CU1 central unit and the ADN PS power supplies, set the on/off
switch or to position “I”.
The central unit switches on and its display panel lights up. The power supplies
switch on and their status LEDs light up:
Switching the conference system off
왘 Set the on/off switch of the ADN CU1 central unit to position “0”.
The central unit is switched off and the display panel goes off. All ADN PS power
supplies connected to the central unit and switched on are switched off and the
status LEDs go off.
To switch individual AD
N PS power supplies off:
왘 Set the on/off switch of the ADN PS power supply to position “0”.
The power supply is switched off and all
status LEDs go off. Additional con-
nected ADN PS power supplies are also switched off.
To completely switch the ADN CU1 central unit or the ADN PS power supply off:
왘 Pull out the mains plug from the wall socket.
The ADN PS power supplies can only be switched on when the ADN CU1 cen-
tral unit and the previous ADN PS connected in series are also switched on.
You can set up your conference system so that you ca
n increase or reduce
the number of conference units used by simply switching individual ADN PS
on or off.
ADN PS ADN PS
ADN CU1
ESC
ON
ADN CU1
ON ON
ADN CU1
ADN CU1
ADN PS
ESC
1
2
3
4
5
Status LED Color Meaning
POWER green ADN PS is switched on
PORT I /PORT II
output 1/
2
– not used, switched off
orange Conference units are connected in strings
green Conference units are connected in
redundant ring topology via output 1
and 2
flashing
orange
Error in a cable string;
output is switched off
1
2
5
3
4
1
2