User Manual

21
PULL OUT EXTRA LENGTH OF EACH OF THE A/V
AND POWER CABLES, ATTACH THEM AND TEST THE
UNIT FOR FULL FUNCTIONALITY PRIOR TO ADDING
SEALANT TO THE BACK OF THE GLASS
AFTER VERIFYING THE A/V AND ELECTRICAL
CONNECTIONS APPLY A LIBERAL ENOUGH AMOUNT
TO SURROUND THE OUTER LIP OF GLASS THAT
SURROUNDS THE BLACK METAL HOUSING NOTING
THE MANUFACTURES DESIGNED USAGE.
A
A
BRING ALL A/V AND
ELECTRICAL CONNECTIONS
UP INTO THE BOTTOM OF
THE BACK BOX'S OPENING
FROM INSIDE THE WALL
CAVITY PRIOR TO
INSTALLING LCD UNIT.
(2)
INSTALL BACK BOX
INTO ROUGH OPENING
SECTION A-A
MOUNT BACK BOX
TIGHT TO THE FINISHED
WALL SURFACE
MOUNTING LOCATION
SHOWING SUPPLIED HARDWARE
12
7
8
"
WALL
OPENING
327
18
1
2
"
WALL
OPENING
469.9
19"
GLASS
DIMENSION
482.6
13
1
4
"
GLASS
DIMENSION
336.6
1
4
"
6.4
3
16
"
4.8
3
16
"
4.8
1
4
"
6.4
(1)
CREATE ROUGH OPENING
WITH THE SEALANT AROUND THE GLASS,
INSERT THE LCD ASSEMBLY INTO THE
BACK BOX MOUNTING THAT HAS BEEN
ALREADY INSTALLED. SLOWLY COMPRESS
THE ADHESIVE UNTIL THE BACK OF THE GLASS
IS TIGHT AGAINST THE WALL SURFACE.
VERIFY THAT SEALANT IS SURROUNDING THE
ENTIRE PERIMETER OF THE GLASS FACE.
SEALANT BEFORE
UNIT IS ENGAGED
SEALANT AFTER
UNIT IS ENGAGED
(3)
VERIFY FUNCTIONALITY
&
APPLY SEALANT
(4)
FINAL INSTALLATION
30 SEP 2015
Date Created
-
Drawing ID Number
IWT-19.5
Model Number
Revised Date
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DOCUMENT
IS THE SOLE PROPERTY OF THE MANUFACTURER. ANY
REPRODUCTION IN PART, OR AS A WHOLE, WITHOUT
THE WRITTEN PERMISSION OF MANUFACTURER, IS
PROHIBITED.
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/8"
ANGULAR:
1.0
TWO PLACE DECIMAL:
.03"
THREE PLACE DECIMAL:
.015"
SHEET
3
Schematic: 19” Model