Operation Manual

13
9. Instructions for using freezer
10. Ice-cube tray
11. Storage shelf
12. Compressor
13. Melt-water evaporation tray
14. Condenser
Before using for the rst time
Remove any exterior and interior packaging materials
completely, including the adhesive strips.
The packaging materials must be properly disposed of.
Fit the two enclosed spacer elements (1) into the
corresponding guide slots on the rear (2).
Before it is connected to the mains, the unit must be
thoroughly checked for transport damage, including its
power cord.
Clean the unit as described in the section De-frosting and
cleaning.
The unit should only be transported in its vertical position;
do not tilt any more than 30°.
Once the unit has been positioned, wait for about 30
minutes before it is connected to the mains.
If the unit has been tilted more than 30° during transport,
allow it to stand upright for at least 4 hours before it is
connected to the mains.
When the unit is rst switched on, a slight ‘new’ smell may
be noticed. However, this will disappear once the cooling
process has begun.
Installation
The appliance should be set up in a well-ventilated, dry room.
It should be operated in conditions where the relative
humidity is no more than 70 %.
The product data sheet at the end of this manual contains
details of the ambient temperature range suitable for this
appliance.
Do not use the appliance outdoors.
Ensure that the plug is accessible and can be removed from
the wall socket at any time.
Do not expose the appliance to direct sunlight, and do not
position it next to any heat sources (radiators, cookers etc.). If
this cannot be avoided, however, suitable insulation must be in
installed between the heat source and the unit.
The unit must not be installed inside a cabinet, nor directly
below a hanging cupboard, shelf or similar object.
In the case of uneven oors, the adjustable feet on the unit
can be used to compensate and ensure optimum stability.
Set-up dimensions
Ventilation
The heated air around the rear of the unit must be able to circulate
freely.
Ensure, therefore, that the air circulation behind the unit is not
obstructed.
Caution: Ensure at all times that the rear ventilation
openings around the top cover are not obstructed.
Reversible door
If required, the door may be reversed, i.e. from right-hinged (default
installation) to left-hinged.
To avoid the risk of personal injury or damage to the unit, two people
are needed to reverse the door.
Warning: Always disconnect the unit from the mains before
any maintenance or repair work is carried out.
Before you get started, please note the following:
Always ensure that the correct number of washers is used
on all hinge bolts and screws.
So that the doors can close tightly against the frame, take