Operation Manual, User's Manual

1-23
BEFORE USING THE MACHINE►BEFORE USING THE MACHINE
PREHEAT MODE
This mode lowers the temperature of the fusing unit and makes the machine wait in low power consumption state.
Preheat mode will activate when the set duration of time elapses in waiting status without executing a job.
Compared to Auto Power Shut-Off Mode, the amount of energy saved is less and the wakeup time is shorter.
In the preheat mode, the [Home Screen] key is lit and the light goes off for the touch panel and the [Power Save] button.
The touch panel is cleared when it is tapped or the [Home Screen] button is pressed.
A message appears 15 seconds before Preheat Mode is entered.
To close the message and continue normal operation, tap the [Continue] button.
If no action is taken within 15 seconds after the message appears, the machine enters preheat mode.
AS SOON AS THE REMOTE JOB IS FINISHED, ENTER
AUTO POWER SHUT OFF MODE
Printing or outputting received fax data in Auto Power Shut-Off Timer turns on the power, and then the machine returns
to Auto Power Shut-Off Mode immediately after completing the print job.
Fix transition time.
The Auto Power Shut-Off Timer is fixed. Select [Fix transition time.], and set the transition time in [Auto Power Shut-Off
Timer].
When this setting is enabled, the [Change transition time by time of day.] option is disabled.
To set preheat mode:
"Settings (administrator)" → select [System Settings] → [Energy Save] → [Eco Setting] → [Preheat Mode Setting].
To set display of the message:
In "Settings (administrator)", select [System Settings] → [Energy Save] → [Eco Setting] → [Display Message When
Extending Transition Time to Preheat/Auto Power Shut-Off Mode].
To set "As soon as the remote job is finished, enter Auto power shut off mode.":
In "Settings (administrator)", select [System Settings] → [Energy Save] → [Eco Setting] → [As soon as the remote job is
finished, enter Auto power shut off mode.].
L
1
L
L
H
Printed
Sleep mode
Print
Sleep mode
Fusing unit is turned
off
Fusing unit is turned
on
Fusing unit is turned
off