Service manual

5 – 3
b) Remove the tube cover.
Insert the (–) screwdriver to A hole and then lean it to the
right as lifting B part.
c) Remove the evaporator from the cabinet.
Take off the catch of the tube cover from the plate and move
the evaporator upward.
14) Lift the bottom part of the side cover R and remove the side
cover R..
15) Loosen the screw of cross flow fan and separate the cross flow
and the fan motor.
When assembling them, insert the motor shaft in the boss of the
cross flow fan to the ring position.
16) Take off the catch of guide R from cabinet and remove the guide.
17) Remove the plasmacluster holder from the cover while taking off
the both sides catches of the cover. (For the models with plasma-
cluster).
18) Take out the plasmacluster unit from the holder after taking off the
catch of it. (For the models with plasmacluster)
19)
For the models with the auto horizontal adjustment function.
Remove the 2 screws and take out the louver motor V assemblies.
Remove the louver motor cover after t
aking off the catches of it.
Catch
Screw
Screw
c
A
B
side cover R
catch part
Ring
side cover R
catch part
louver motor cover
louver motor base
fan