Service manual

7
AF-R100CX
AF-R120CX
SUGGESTED TOOLS
1. Screw driver (medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
INSTALLATION
These models can also be installed through the wall with
the optional through the wall mounting kit, model AZ-
80WK. To order this kit either contact your dealer or call
1-800-BE-SHARP.
The wall opening dimensions for through the wall installation
are:
25" (635mm) (W) x 17 -1/ 4 " (438mm) to 17-3/ 4"
(451mm) (H) x 4" (102mm) minimum (D).
Complete instructions are included with the wall mounting
kit.
WARNING: Make sure the unit is turned off and
unplugged before working.
1-1. Cut the window sash foam seal (adhesive type) to the
proper length and attach it to the underside of the
window sash.
1-2. Attach the bottom gasket to the outer side of the
window sill.
2-1. Unscrew the 2 screws at the corners of the front panel.
Keep them as they will be used later.
2-2. Remove the front panel by pulling the front panel at the
lower corners towards you about an inch.
Next lift it up and pull it towards you.
CAUTION: Take care not to damage the exhaust
lever when removing the front panel.
3-1. Unscrew the 6 stopper screws of the cabinet. Keep
the 4 screws from the top and front , as they will be
used later.
3-2. Slide the chassis out from the cabinet by pulling on the
hand hold located at the bottom center of the chassis.
bottom gasket
window sash foam seal
(adhesive type)
Front panel
Exhaust Lever
Front
panel
Horizontal
Louver
Closure assembly
Cabinet
sill
incline backwards about 1cm (3/8")
CAUTION Do not remove any material (ex.
styrofoam, etc.) from inside the unit.
4. Insert the right closure assembly and the left closure
assembly into the top angle and the bottom channels.
Secure the right and left closure to the cabinet with 6
of the provided screws. (L= 13/ 32 ", 10 mm)
5. Open the window sash and place the cabinet on the
sill. Close the window sash securely behind the top
angle.If there is space between the bottom channel
and the sill, fill the gap with a thin board or other hard
filler.
WARNING:
At this step, make sure the cabinet is inclined
approximately 1 cm (3/8) to the back. If the cabinet is
not properly inclined, the water collected in the bottom
tray during operation will not drain properly and may
flow into the room where the air conditioner is installed.