User Manual

11
Setup
Entering SETUP MENU
Connect AN-LS1 to a computer using RS-232C or Telnet, and open the SETUP MENU on the computer
to carry out various settings for AN-LS1.
When Connecting Using RS-232C
1 Launch general purpose terminal emulator.
2 Set settings for the RS-232C port of the terminal emulator as follows.
Baud Rate : *9600 bps
Data Length : 8 bit
Parity Bit : None
Stop Bit : 1 bit
Flow Control : None
* This is the default value. If the value of Baud Rate for AN-LS1 has been changed, set Baud Rate
here according to the changed value on AN-LS1. (Page 19)
3 Connect the plug for the AC adapter to a wall outlet to supply the power while holding
down the “A” (or “a”) key on the terminal keyboard.
4 Keep holding down the “A” (or “a”) key for more than 3 seconds. Setup Menu Enable
will be displayed.
5 Press the return key on the terminal keyboard.
6 Input setup and press the return key.
7 User Name: is displayed. Input the user name and press the return key.
(If a user name has not yet been set, just press the return key.)
8 Password: is displayed. Input the password and press the return key.
(If a password has not yet been set, just press the return key.)
9 Input setup and press the return key.
| SETUP MENU will be displayed.
S E T U P M E N U
[1]IP Address [2]Subnet Mask [3]Default Gateway
[4]User Name [5]Password
[6]RS-232C Baud Rate [7]Unit Name
[A]Advanced Setup [D]Disconnect All
[V]View All Setting [S]Save & Quit [Q]Quit Unchanged
setup>
User name and password are not set in the initial settings.
If the user name or password is entered incorrectly three times, SETUP MENU will be quit.