Operating the Monitor Using a PC (IP control)
Command list
Any commands not listed in the following table are out of operation guarantee range.
Function “A”part “B”part Part operation description Remarks
Power POWR 0 Power off Transition to standby
Input change Toggle ITGD 0 (Toggle)
INPUT 1 to 4 (HDMI) IAVD 1 to 4 (Input terminal number) Change to INPUT 1 to INPUT 4
INPUT 5 (video) IAVD 5 Change to INPUT 5
INPUT 6 (analog RGB) IAVD 6 Change to INPUT 6
INPUT 7 (8K: HDMI×4) IAVD 7 Change to INPUT 7
INPUT 8 (8K) IAVD 8 Change to INPUT 8
AV MODE AVMD 0 (Toggle) Toggled among currently selectable items
504 USER1
505 USER2
506 USER3
7PC
500 PC2
9sRGB
6DYNAMIC
In standby mode, this monitor can not be turned on by IP control.
6-4