Service manual

AYAP7FHR
5 – 2
[2] PERFORMANCE CURVES
NOTE: 1) Indoor fan speed : Hi
2) Vertical adjustment louver “45°”, Horizontal adjustment louver “Front”
3) Indoor air temp. : Cooling 27°C, Heating 20°C
4) Power source : 230V, 50Hz
1. AY-AP7FHR
1.1. Cooling 1.2. Heating
2. AY-AP9FHR
2.1. Cooling 2.2. Heating
25 30 35 40
2.6
2.4
2.2
2.0
12
10
8
800
700
600
500
Cooling capacity(kW)
Outside air temp.(ºC)
Input(W)
Outlet air temp.(ºC)
40
35
30
800
700
600
500
3.0
2.5
2.0
1.5
Outlet air temp.(ºC)
-5 0 7510
Heating capacity(kW)
Outside air temp.(ºC)
Input(W)
25 30 35 40
3.2
3.0
2.8
2.6
2.4
12
10
8
1000
900
800
700
Cooling capacity(kW)
Outside air temp.(ºC)
Input(W)
Outlet air temp.(ºC)
40
35
30
1000
900
800
700
3.5
3.0
2.5
2.0
Outlet air temp.(ºC)
-5 0 7510
Heating capacity(kW)
Outside air temp.(ºC)
Input(W)