Memory function setting
When the unit is shut off, press the MODE button for 10
seconds to switch set values so as to decide if the unit
operating status or shut off status is memorized after a
power fail.
If the set temperature area displays "01", it means the
unit operating status or shut off status shall be memorized
after a power fail; "02" means the operating status or shut
off status will not be memorized.
Press the ON/OFF button to store the set value and exit
the setting.
Even if the ON/OFF button is not pressed, the system
will store the set value and exit the setting after 10
seconds, and return to the normal unit off display.
Failure display
When there is failure in the unit operation, the “ERROR”
will ash on the display of the wire controller and the
error code will also be displayed. When there are multiple
failures, the error codes will be displayed one after one
on the wire controller. The two digits indicate the detailed
the error code.
The Error Codes Denitions are as Follows:
Error code Fault
E0 Water pump malffunction
E1 High pressure protection of compressor
E2 Indoor anti-frozen of compressor
E3 Low pressure protection of compressor
E4 Air discharge high-temperature protection of compressor
E5 Overload protection of compressor
E6 Transmit malfunction
E8 Indoor fan protection
E9 Water ow protection
F0 Malfunction of indoor environment sensor at air return vent
F1 Evaporator sensor malfunction
F2 Condenser sensor malfunction
F3 Outdoor environment sensor malfunction
F4 Malfunction of air discharge sensor
F5 Malfunction of environment sensor on displayer
FF Connected control communications Failure
EE Buttons are locked (not failure)