INSTALLATION INSTRUCTIONS
Iinstallation notes
Location
The air conditioner must be rmly installed and 3~4 liability checks must be done every year.
Avoid place within easy reach of young children.
Keep TV set, radio and the like 1 m or more away from the unit and the remote controller.
Do not install the unit in a place where inammable gas may leak. It may cause re.
At salty coastal areas or special areas such as the vicinity of a sulphurous hot spring, please contact dealer
before installation to make sure it is safe to use the unit.
Not to be installed in laundries.
Select a place so as not to annoy neighbor with the hot air or noise.
Installatton/removal/repair
Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric shock, water leak,
re etc. Consult your dealer or other qualied service personnel for the installation/removal/repair of the unit.
Be sure to use only the specied accessories and parts for installation, failure to use may lead to electric
shock, leakage or re.
Carry out installation with consideration of strong winds, typhoons, or earthquakes. Improper installation work
may result in accidents due to fall of equipment.
Wiring arrangement
Prepare a dedicated power supply circuit.
The cable must be installed by professional technicians.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualied person in order to avoid a hazard. Use only the manufacture-specied power cord for replacement.
The appliance shall be installed in accordance with national wiring regulations. Improper cable connection can
cause the power supply cord, plug and the electrical outlet to overheat and cause re.
Fit a disconnect switch, having a contact separation of at least 3mm in all poles, to the electricity power line.
Indoor unit installation
Installation spaces
Selection of the installation site
There shall be no obstacle at the inlet and outlet so as to keep the air in good circulation.
Ensure the space needed for installation, repair and maintenance works.
The horizontally of the installation place should be guaranteed.
The drainage hose shall be easy to drain water.
Make sure that there are enough space for care and maintenance. Make sure that the height between the
indoor unit and ground is above 1800mm.
When installing the lifting bolt, check if the install place can withstand the weight 4 times of the unit’s. If not,
reinforce before installation. (Refer to the model paper and nd where should be reinforced)
NOTE:
There will be substantial amount of lampblack and dust in dining room and kitchen, which would reduce the
capacity of heat exchanger, result in water leakage and abnormal operation of the water pump.
Ensure that the smoke trap above cooker has enough capacity to prevent the indraft of the lampblack by the
air conditioner.
Install the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner.
H
MIN.20
MIN.1500
MIN.1500
MIN.1800
Length unit: mm
GREE_cassette_eng.indd 20 08.10.28 11:42:45 AM