Set NiBG Alarm information includes (Fig. 40):
> Graphic NBG (meaning Nitrogen Bar Graph).
> NiBG Set Point (segments), flashing.
• Pressing and releasing the S button momentarily and
repeatedly (< 2 sec each time) will step through the Set
Point from all 5 segments (Deco) to 1 one at a time.
• Pressing and releasing the A button momentarily (< 2 sec)
will save the setting and access Set DTR Alarm.
• Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert to the Set A screen.
• Depressing the M button for 2 seconds, or if no button is
pressed for a period of 2 minutes, operation will revert to
the NORM (or GAUG) Surface Main screen.
FREE Mode has a separate NiBG Alarm.
Set DTR Alarm information includes (Fig. 41):
> Set Point value (hr:min), flashing, with wave/clock/profile
icons.
• Depressing the S button will scroll upward through the
Set Points from 0:00 to 0:20 (:min) in 1 minute (0:01)
increments at a rate of 8 per second.
Fig. 40 - SET NiBG ALARM
Fig. 41 - SET DTR ALARM
Wave over Clock over
Prole icon represents