Set Units information includes (Fig. 45):
> Set Point icons/graphics F and FT (or C and M), flashing.
• Pressing and releasing the S button momentarily (< 2 sec)
will toggle between Imperial (F, FT) and Metric (C, M).
• Pressing and releasing the A button momentarily (< 2 sec)
will save the setting and access Set Deep Stop.
• Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert to the Set U screen.
• Depressing the M button for 2 seconds, or if no button is
pressed for a period of 2 minutes, operation will revert to
the NORM (or GAUG) Surface Main screen.
Set Deep Stop information includes (Fig. 46):
> Graphic DS (meaning Deep Stop).
> Set Point ON or OFF, flashing, with STOP icon.
• Pressing and releasing the S button momentarily (< 2 sec)
will toggle the Set Point between OFF and ON.
• Pressing and releasing the A button momentarily (< 2 sec)
will save the setting and access Set Safety Stop.
• Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert to the Set U screen.
• Depressing the M button for 2 seconds, or if no button is
pressed for a period of 2 minutes, operation will revert to
the NORM (or GAUG) Surface Main screen.
Fig. 45 - SET UNITS
Fig. 46 - SET DEEP STOP