Owner`s manual

60
• Pressing and releasing the A button momentarily 2 times (< 2
sec each time) while viewing the NORM Plan Lead-in screen,
or the S button1 time (< 2 sec) while viewing the GAUG
Surface Main screen, will access Fly Mode.
NORM SURF MAIN >> PLAN >> FLY
GAUG SURF MAIN >> FLY
Time to Fly information includes (Fig. 54):
> Graphic FLY.
> Countdown Time (hr:min) with clock icon.
• If accessed from the NORM Plan Lead-in screen, pressing and releasing the A button
momentarily (< 2 sec) will access the Desat Time screen.
• If accessed from the GAUG Surface Main screen, pressing and releasing the A button
momentarily (< 2 sec) will revert to the GAUG Surface Main screen.
• Depressing the M button for 2 seconds, or if no button is pressed during a 2 minute
period, operation will revert to the NORM (or GAUG) Surface Main screen.
• Pressing the L button will activate the Backlight.
DESAT MODE (NORM only)
The Time to Desaturate counter provides calculated time for Tissue Desatuation at sea level
taking into consideration the Conservation Factor setting. It begins counting down 10
minutes after surfacing from a dive, counting down from 23:50 max to 0:00 (hr:min).
Fig. 54 - TIME TO FLY