Owner`s manual

80
DELAYED VIOLATION #2 (DV2)
If the Decompression obligation requires a Ceiling Depth be-
tween 60 FT (18 M) and 70 FT (21 M), the full NiBG and TAT
(Total Ascent Time) digits will flash.
When this occurs, you must make a controlled ascent to just
deeper than, and stay as close as possible to, 60 FT (18 M)
without causing the NiBG and TAT to flash. When the Deco
Stop Depth indicates 50 FT (15 M), etc., you can ascend to
those Stop Depths and continue decompressing.
DV2 Main information includes (Fig. 75) -
> Full NiBG (flashing), O2BG if applicable
> TAT (hr:min) flashing with Deco mode icon
> Stop Depth with FT (or M) icon and STOP icon
> Stop Time (hr:min) with clock icon
> Tank icon (Gas 1 or 2)
> Current Depth with FT (or M) icon
• Press and release the A button (< 2 sec) to view ALT screens
which are similar to those previously described for the
Deep Stop (page 73).
• Depress the M button for 2 seconds to access the Gas
Switch Routine.
• Press the L button to activate the Backlight.
Fig. 75 - DV2 MAIN