RESU 3.3, 6.5, 10, RESU Plus

Table Of Contents
Battery Pack Installation
6. There are screw holes for mounting brackets
on the top of the both sides of the battery pack.
Drive the M5 screws through the mounting
brackets into the holes and tighten them to a
torque of 5 N·m.
4.7 Cable connections
WARNING
Make sure that the inverter is turned o before connecting the battery pack to the
inverter.
4.7.1 Connecting ground wire
ON
O
FF
C
ONNE
C
T
ION K
IT
Grounding between the battery pack and the inverter is not mandatory but recom-
mended.
1. Feed the ground wire from the inverter or RESU Plus through a small grommet
and then through the bottom of the small cable entries.
2. Connect the ground wire to the ground screw, and tighten it to a torque of 4 N·m.
The screw type is M5.
3. Push the grommet into the cable entry.
27