RESU 3.3, 6.5, 10, RESU Plus

Table Of Contents
RESU Plus Installation
5.4.2 Connecting ground wires
Grounding between the battery pack and the inverter is not mandatory but recom-
mended.
1. Loosen the sealing nuts of the small glands that are closest to the edges.
2. Feed ground wires through the glands.
3. Connect each ground wire to its corresponding ground point. Use the ground
point at the lower left for the rst battery pack, the one at the lower right for the
second battery pack, and the one at the upper for the inverter.
4. Tighten the sealing nuts rmly.
5.4.3 Connecting power cables
To supply power to the RESU Plus for its operation, connect the provided power cables
from the battery packs to the RESU Plus.
NOTE
Power cables must connect from both battery packs to ensure that the RESU Plus
operates normally even when either battery pack is o.
1. Loosen the sealing nuts of the small glands in
the middle.
2. Feed power cables through the glands.
36