Conguration Switches
stalled, they must be connected to a RESU Plus. In the case, they are indirectly
connected to the inverter via the RESU Plus, and thus the switch must be set to
0010
2
.
The number of battery packs
Value
Setting
1
0011
1
2
0010
2
6.1.2 Setting for battery cell type
Make sure that the Cell select DIP switch is set to 00
2
.
6.1.3 Settings for CAN bus pins
Make sure that the CAN_H rotary switch is set to 4. This switch indi-
cates which pin is used for CAN high signal by the inverter.
Make sure that the CAN_L rotary switch is set to 5. This switch indi-
cates which pin is used for CAN low signal by the inverter.
Make sure that the GND rotary switch is set to 2. This switch indicates
which pin is used for ground by the inverter.
Only 1st to 5th pins can be used.
CAN_H CAN_L
GND
Setting
4
5
2
6.1.4 Setting for terminal resistors
Make sure that the TermRes DIP switch is set to 11
2
.
Bit On O
1 CAN terminal resistor attached CAN terminal resistor unattached
2 Unused Unused