RESU 10M

Attachment 1. Battery Technical Specifications
Table 1.1 Specification Overview of RESU13
Items
RESU10M
Electrical
Cell
JH3
Configuration
42S 1P
Battery Capacity
63.0Ah
Nom. Voltage/ Operating Voltage Range
155.4 V / 126 ~ 176.4V
Total Energy Capacity
9.786 kWh
Max. Power / Max. Current
5kW / 40A (@Min. Voltage)
Standard Charging
Condition (CCCV)
Charging Current
18.9[A], Ambient 25
Cut off Condition
3.15A @ 176.4V, Ambient 25
Std. Discharging
Condition (CC)
Discharging Current
18.9[A], Ambient 25
Cut off Condition
Pack voltage 126 V or Min. Cell voltage 3V
Battery pack Round-trip Efficiency
>95% (under specific condition)
Communication Interface
CAN 2.0b Standard ID (500kbps)
DC Disconnect
Circuit Breaker, Contactor, Fuse
Environmental
Installation location
Indoor(Wall-mounted/Support Base) /
Outdoor (Wall-mounted/Support Base)
[if installed outdoors, do not allow the battery pack
to be exposed to direct sunlight and moisture]
Operating Temperature Range
-10 ~ 50
Optimal Range
15 ~ 30
Storage Temperature Range
1) - 30 ~ 60 (acceptable for 7 days in total)
2) - 20 ~ 45 (acceptable for the first 6 months)
3) - 20 ~ 30 (acceptable for 7
th
month~12
th
month)
Operating Humidity Range
5 ~ 95%, RH (Non Condensing)
Altitude
Max. 2,000m
Cooling Strategy
Natural convection
Reliability &
Certification
Safety
Cell
UL1642
Battery Pack
IEC 62619 / IEC 60950(LVD) / CE
Hazardous Materials Classification
Class 9
Transportation
UN38.3 (UNDOT)
Ingress
IP55