-Error Messages-
"
A number or symbol appears in (*) position.
"
Messages shown in the brackets are shown on the
remote control.
ERROR MES-
SAGES
MEANING
NAME FULL
"
The number of a disc, group, or track
name exceeds 40.
(Shorten the name.)
NO DISC
(NoDISC)
"
A disc has not been loaded.
NO SIGNAL
(noSIG.)
"
Poor connection of the digital cable.
"
No output signal comes out from the
connected unit to playback.
(Use the AC power for the connected
unit.)
"
The input signal has improper sam-
pling frequency.
NO TRACK
(NoTRACK)
"
There is no track to be played.
PLAY MD
(PLAYmd)
"
You tried to record on a playback-only
disc.
POWER?
"
AC adaptor other than specified.
"
Abnormal voltage detected.
PROTECTED
"
The write protection tab of a MiniDisc
is set to the protected position.
SORRY
(Sorry)
"
Cannot operate this unit whilst search-
ing/updating groups and track num-
bers.
(Wait for a while and try the operation
again.)
ERROR MES-
SAGES
MEANING
TOC FORM
(**)
"
There is an error in the recording sig-
nal.
(Erase all of the tracks, and then record
again.)
TOC FULL
(T-FULL)
"
There is no space left for recording
character information (track names,
disc names, etc.).
TEMP OVER
"
The temperature is too high.
(Turn off the power, and wait for a while.)
Tr. Protect
"
The track has been protected from be-
ing erased.
(Edit the track with the device on which it
was recorded.)
?DISC
"
A disc which contains data other than
music was played.
(A disc which contains nonmusic data
cannot be played.)
? Gr Form
"
The group recording or the GROUP
RESERVE function cannot be per-
formed.
(Erase the disc name and retry the same
operation.)