Owner`s manual

- 117 -
EO1-11116
MA-516-100 SERIES
REG
22. System Option Setting
This chapter is provided for your selections of the register’s basic functions according to the market and your
requirements, some of which are already indicated for reference in other chapters as to print/non-print items, key
functions, etc.
Programming Procedure
The System Options are divided into 16 addresses and each address is further divided into a maximum of 8 bits (Bits
1 to 8). Each Address table is placed on the following pages.
Condition: After Daily Financial Reset
(refer to “NOTE on Condition” on page 22)
Programming Procedure:
Use the MA Key to turn the Control Lock to “SET”
or the S Key to turn the Control Lock to “BLIND”.
OFF
Z
REG
X
SET
MGR
-
→
→
→
Repeat for Bit status changes in all the required Addresses.
Address No.
(max. 2 digits;
1 to 16)
To access Addresses 1 to 11:
To access Addresses 1 to 13:
1
1
1
8
1
8
#/NS
→→
ST
AT/TL
Bit Nos. that are set to “SET” status (max. 8 Bit
Nos., combination of 1 to 8)
OFF
X
SET
MGR
-
@/FOR
To access all Addresses 1 to 16
( or )
#
Enter a maximum of eight-digit number composed of Bit Nos. whose status must be set to the “SET” status in
the Address. If there is no Bit Nos. to be set to the “SET” status, enter “0” for the Address.
Examples) To SET Bit 2 only ..................... Enter 2.
To SET Bits 2 and 3................. Enter 23.
To SET all the Bits ................... Enter 12345678.
To RESET all the Bits .............. Enter 0.
To change any Bit in an Address, enter the Address No. and enter all the SET Bit Nos again. If a Bit No. is not
included in the SET Bit Nos, the Bit will be RESET.
Z