Service manual

4
R-630DK
R-630DW
R-630DS
ITEM DESCRIPTION
Power Requirements 120 Volts / 14 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output 1100 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions Width 19-1/2"
Height 14"
Depth 20-5/8"
Cooking Cavity Dimensions Width 17-3/4"
Height 8-1/4"
1.4 Cubic Feet Depth 17"
Control Complement Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
P-HI.................................................. Full power throughout the cooking time
P-90 .................................................................... approx. 90% of Full Power
P-80 .................................................................... approx. 80% of Full Power
P-70 .................................................................... approx. 70% of Full Power
P-60 .................................................................... approx. 60% of Full Power
P-50 .................................................................... approx. 50% of Full Power
P-40 .................................................................... approx. 40% of Full Power
P-30 .................................................................... approx. 30% of Full Power
P-20 .................................................................... approx. 20% of Full Power
P-10 .................................................................... approx. 10% of Full Power
P-0 .................................................... No power throughout the cooking time
Breakfast Bar pad, Lunch on the Run pad, One Dish Dinners pad
Super Defrost pad, Compu Defrost pad, Beverage Center pad
Sensor Cooking pads, Custom Help pad, Kitchen Timer/Clock pad
Number selection pads, Power Level pad, Minute Plus pad
STOP/Clear pad, START/Touch On pad
Oven Cavity Light Yes
Safety Standard UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The electrical requirements are a 120 volt 60 Hz, AC only,
15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When
installing this appliance, observe all applicable codes and ordinances.
A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord.