FLUSH MOUNT DIMENSIONS
KIT # SKMD24F0AS/SKMD30F0AS
1/4" FRONT EXTENDED
C
N
H
E
F
D
A
B
J
L
I
M
K
G
Note: the face of the
shelf must sit 1
3
/4"
(44.45 mm) back from
the face of the cabinet.
cabinet face
shelf face
O
C
N
H
E
F
D
B
A
J
L
I
cabinet
face
shelf
face
O
G
K
M
Note: the face of the
shelf must sit 1
3
/4"
(44.45 mm) back
from the face of the
cabinet.
Top view
C
L
22”
mounting cleat
opening width
Anti-Tip block
Mounting
cleat
1-5/16"
Drawer
face
Cabinet
face
Note: the mounting surface of the
finished cleat must sit 1
1
/16"
back from the face of the cabinet
(pushing the face of the drawer out
1
/4").
C
L
Top view
A
B C
Anti-Tip block
Mounting
cleat
Drawer
face
Cabinet
face
Note: the mounting surface of the
finished cleat must sit 1
1
/16"
back from the face of the cabinet
(pushing the face of the drawer out
1
/4").
C
L
Top view
A
B C
Anti-Tip block
Mounting
cleat
Drawer
face
Cabinet
face
Note: the mounting surface of the
finished cleat must sit 1
1
/16"
back from the face of the cabinet
(pushing the face of the drawer out
1
/4").
A. 6" (152.40 mm)
B. Suggested electrical outlet
location
C. Anti-Tip block
D. 5" (127 mm)
E. 3-1/2" (88.90 mm)
F. 4" (101.60 mm)
G. 24-3/16" (614.35 mm) minimum
24-1/2" (622.3 mm) maximum
H. 14-13/16" (376.24 mm) to
bottom of Anti-Tip block
I. 1-1/16" (26.97 mm)
J. 23-1/2" (596.90 mm) minimum
depth
K. 22-1/8" (561.97 mm)
L. 1-3/4" (44.45 mm)
M. 16-7/8" (428.62 mm) opening
N. Floor must support 100 lb
(45.4 kg)
O. 1-3/4" (44.45 mm)
A. 6" (152.40 mm)
B. Suggested electrical outlet
location
C. Anti-Tip block
D. 5" (127 mm)
E. 3-1/2" (88.90 mm)
F. 4" (101.60 mm)
G. 30-5/16" (769.92 mm) minimum
30-5/8" (777.87 mm) maximum
H. 14-13/16" (376.24 mm) to
bottom of Anti-Tip block
I. 1-1/16" (26.97 mm)
J. 23-1/2" (596.90 mm)
minimum depth
K. 28-7/16" (722.3 mm)
L. 1-3/4" (44.45 mm)
M. 16-7/8" (428.62 mm) opening
N. Floor must support 100 lb
(45.4 kg)
O. 1-3/4" (44.45 mm)
24" MICROWAVE DRAWER 30" MICROWAVE DRAWER
A. 28-1/2" (723.9 mm) mounting cleat opening width
B. 1/4" (6.35 mm)
C. 1-1/16" (26.97 mm)
A growing trend in the installation of kitchen appliances is mounting flush. This allows the consumer to present
their appliances with a clean, flush with the cabinet face appearance. In this installation type, there are two ways to
accomplish this look: ¼” front extended and true flush.
In the ¼” front extended application, the appliance can be mounted slightly “proud” of the cabinet cutout, which will
create a flush appearance. Having the ¼” extension also allows to hide the cabinet cutout edges.
In the true flush application, the appliance is mounted just as described, truly flush with the cabinet face. However,
due to the appliance face and the cabinet face being on the same plane, the cabinet cutout edges will be visible and
exposed. It is recommended in this true flush installation to finish / stain these edges.