Installation Instructions

E 4
MICROWAVE DRAWER FLUSH MOUNT, MEASUREMENTS AND INSTALLATION INSTRUCTIONS
D
G
A
B
C
J
H
I
F
E
Figure 1
A. 21
5
/8" (549.28 mm)
B. 4
11
/16" (119.06 mm)
C. 1
3
/4" (44.45 mm)
D. 21
7
/8" (555.63 mm)
E. 23
5
/8" (600.07 mm)
F. 16" (406.4 mm)
G. 14
19
/32" (370.68 mm)
H. 1
17
/32" (38.89 mm) door thickness
I. 15" (381 mm) auto drawer opening
J. 4" (101.60 mm)
1. Prepare cabinet opening as shown in Figure 2.
C
L
H
E
F
D
N
N
A
B
J
I
M
K
G
I
I
Figure 2
A. 6" (152.4 mm)
B. Suggested electrical outlet
location*
C. Anti-Tip block
D. 5" (127.0 mm)
E. 3
1
/2" (88.9 mm)
F. 4" (101.6 mm)
G. 30
5
/16" (769.9 mm) min
30
5
/8" (777.9 mm) max
H. 14
13
/16" (376.2 mm) to
bottom of Anti-Tip block
I. 1
17
/32" (38.9 mm) Refer to
Figure 3 **
J. 23
1
/2" (596.9 mm)
minimum depth
K. 22
1
/8" (562.0 mm)
L. Floor must support 100 lb
(45.4 kg)
M . 16
1
/4" (412.8 mm) opening
* See Figure 4 letter C for
detail
N. Allow 4
1
/8" (104.4 mm)
Figures 1 and 2 contain many Microwave Drawer measurements for
reference when planning the drawer’s location.
This Microwave Drawer can be installed below any electric, gas wall
oven, electric induction and/or gas cook tops.
* Can also be installed using an electrical outlet in an adjacent
cabinet within the area where the provided electrical cord can
reach. Power cord access hole in cabinet should be a minimum
1
1
/2" diameter hole and deburred of all sharp edges.
IMP O R TANT
Always allow sufcient power cord length to the
electrical outlet to prevent tension.
Always check electrical codes for requirements.
C
L
Top view
A
Anti-Tip block
Mounting cleat
B
C
Drawer face
Trim
face
Note: the mounting
surface of the finished
cleat must sit 1
17
/32"
(38.9 mm) back from
the face of the cabinet.
**
Figure 3
A. 22
1
/8" (596.9 mm) mounting cleat opening width
B. 0"ush
C. 1
17
/32" (38.9 mm) front of cleat to cabinet face
Note: For pre-existing 30” cabinet openings that desire a standard
mount,llerpanelswillneedtobeinstalledoneithersideofthe
cutout to properly mount the extension kit panels.