Specifications

2.2 220/240V CONVERSION
NOTE: In areas where 240 volts is the standard, the connectors on the ac
drive board must be repositioned as explained below. This
procedure is also done after step 1 of the copier installation
procedure.
1) Remove the rear cover (4 screws).
2) Disconnect the short connector [A] (2P/White) on the ac drive board [B]
from CN421 and reconnect it to CN 421 as shown in the illustration.
3) Disconnect the transformer connector [C] (3P/White) on the ac drive
board from CN417 and reconnect it to CN417 as shown in the illustration.
4) Reinstall the rear cover.
5) Change the data of SP mode #12 from "0" to "1". (Step 17 explains how
to access the SP mode.)
[B]
[C]
[A]
240V
220V
220V
240V
1 December 1990
3-10