Specifications

Access Procedure 2 - DIP switch 101-4
1. Turn the main switch off.
2. Remove the rear cover and turn on DIP SW 101-4, then turn on the main
switch. "5" will blink in the copy counter and the ADS indicator or a
Manual Image Density indicator LED will blink.
3. Using the numeric key board, enter the desired SP mode number. (SP
mode numbers are given in the Service Program Mode table.) The SP
program can also be selected with the zoom keys (+, –).
NOTE: To cancel an already entered program, press the Clear key.
4. Press the Enter key to view data.
NOTE: If an invalid SP number has been entered and the Enter key (#) is
pressed, the display on theoperation panel does not change.
5. To leave SP mode, turn the main switch OFF, turn off DIP SW101-4, and
turn the main switch on.
2.1.2 Change Adjustment Values or Modes
1. Follow steps 1-5 in access procedure 1 and steps 1-3 in access
procedure 2.
2. The factory-set value or mode will be displayed in the Magnification
indicator.
3. Enter the desired value or mode using the numeral keys. (SP mode
numbers are given in the Service Program Mode table.)
4. To leave SP mode, press the Clear Modes key (access procedure 1) or
turn off the main switch and DIP SW101-4 (access procedure 2).
1 December 1990
4-8