Specifications

2.1.3 Memory Clear Procedure
<SP-98 "Clears all counters">
Service Program SP-98 is used to clear all counters (copy counters, PM
counter, self-diagnostic counters, misfeed counters). The procedure is as
follows:
1. Turn off the main switch.
2. Turn on DIP SW101-3 & 4 on the main board and turn on the main switch.
3. Select Service program SP-98 and press the "1" key on the key pad, then
press the Enter key.
At this point all counters will be cleared to "0".
4. Turn off the main switch.
5. Turn off DIP SW101-3 and 4.
6. Turn on the main switch to resume normal copier operation.
NOTE: When the counters are cleared, the Magnification indicator will
blink 4 times.
<SP-99 "Clear all memory">
This Service Program clears all counters as well as all adjustments and
modes. All modes return to factory settings, and all adjustments returns to
factory settings or defaults.
1. Turn off the main switch.
2. Turn on DIP SW 101-3 and 4 on the main board.
3. Turn on the main switch.
4. Select SP-99 and press the "1" key on the key pad, then press the Enter
key to clear the memory.
NOTE: When the memory is cleared, the Magnification indicator will blink
5 times.
5. Turn off both the main switch and DIP SW101-3 and 4, then turn on the
main switch to resume copier operation.
1 December 1990
4-9