Specifications

Mode No. Function Data Factory
Setting
Comments
12: 220V/240V
Conversion
Selects 220 or 240
volts.
0: 220V
1: 240V
0 If the rated voltage
is 240V, this data
must be changed
to "1". Refer to
NOTE 2.
15: Auto Reset
Time
Selects auto reset
of 1 or 3 minutes,
or cancels this
mode.
0: 1 min.
1: 3 min.
2: None
16: Count
Up/Down
Selects count up or
count down.
0: Up
1: Down
0
17: Auto Feed
Station Shift
Selects auto feed
station shift mode.
0: Auto Shift
1: Manual
0 Copier
automatically shifts
to the cassette or
paper tray holding
same size paper
when paper runs
out.
19: ADS Priority Specifies whether
the copier defaults
to ADS or manual
mode when the
main switch is
turned on.
0: ADS
1: Manual
0
20: APS Priority
(Copier)
Specifies whether
the copier defaults
to APS or manual
mode when the
main switch is
turned on.
0: APS
1: Manual
0 This mode is used
only on the A054
copier.
21: APS Priority
(ADF)
Specifies whether
the copier defaults
to APS or manual
mode when the
original is set on
the DF.
0: APS
1: Manual
1 DF must be
installed on the
machine.
22: SADF Shut-off
Time
Selects shut-off
time for SADF
mode.
0: 5 sec.
1: 60 sec.
0
23: ADF Free Size Enables originals
of various sizes to
be fed from the
same size stack.
0: No
1: Yes
0
24: Factory Use
1 December 1990
4-12