Specifications

Mode No. Function Data Factory
Setting
Comments
25: Margin
Adjustment
in Duplex Mode
Sets the margin
(5 mm) on the right
side of the reverse
page.
0: Yes
1: No
0 Duplex must be
installed on the
machine.
When 1 sided
original mode is
selected, the back
margin (5 mm) is
automatically
added on the right
side of the reverse
page.
27: A3 (DLT)
Double
Counter
Selects single or
double counter of
the total counter in
A3/DLT copies.
0: Normal
1: Double
0
28: Sort Priority Sort Mode is
automatically
selected when
more than1 original
is set on the DF
table and the
entered copy
quantity is greater
than 1 and less
than 21.
0: Manual
1: Auto Sort
0 Sorter and DF
must be installed
on the machine.
When in duplex
mode, more than 2
originals must be
set.
29: Fusing
Temperature
Control
Selects fusing
temperature control
mode.
0: ON/OFF
control
1: Phase
control
0 After selecting the
control mode and
turning the main
switch off/on, the
fusing temperature
control is changed.
30: Black Toner
Supply Mode
Selects black toner
supply system.
0: Detect Mode
1: Fixed Mode
0 See SP 31/SP32
for toner supply
amount.
31: Black Toner
Supply Ratio
(Detect Mode)
Determines how
much toner is
supplied in detect
mode.
0: 15%
1: 7%
2: 30%
3: 60%
0
32: Black Toner
Supply Ratio
(Fixed Mode)
Determines how
much toner is
supplied in fixed
mode.
0: 7.0%
1: 3.5%
2: 10.5%
3: 14.0%
0
33: ID Sensor Bias
(Black)
Sets the bias
voltage applied to
the development
roller for the image
density check.
0: -260V
1: -220V
2: -280V
3: -300V
0 -260V = normal
-220V = lighter
-280V = darker
-300V = darkest
1 December 1990
4-13